Cisco Cisco StadiumVision Mobile Streamer Release Notes

Page of 47
 
 
© 2010-2011 Cisco Systems, Inc. All rights reserved. 
Page 46 of 47 
Considerations for Upgrading DMPs 
Cisco StadiumVision Director currently works with DMP 4310Gs and DMP 4305Gs 
that meets the requirements specified below.  
Table 5.  DMP Requirements 
Device   
Software Release 
DMP 4310G 
Firmware: SE1.0.3, Build 1138 or Build 1408 
DMP 4305G 
Firmware: 5.1.1; Kernel: Linux version 2.4.22 
For step-by-step instructions for installing DMPs, see the StadiumVision Video 
Endpoint (DMP) Design and Implementation Guide.
 
Upgrading DMP 4305Gs 
When using Cisco StadiumVision Director 2.x with DMP 4305Gs, ensure that you 
do the following (in order) via the StadiumVision Management Dashboard: 
  Apply the Initial Config 
  Upgrade the Kernel 
  Upgrade the Firmware 
  Upgrade the StadiumVision Daemon  
  Apply Global DMP settings (as needed) 
See the StadiumVision Video Endpoint (DMP) Design and Implementation Guide for 
more information. 
Downgrading DMP 4305Gs 
With newer DMP 4305Gs (for example, if new DMP 4305Gs are added to an 
existing deployment or a defective DMP 4305G is replaced with a newer one), the 
DMP may be shipped with a later version of firmware and the kernel than is 
supported by Cisco StadiumVision Director. In this case, the firmware and kernel 
need to be “downgraded” to enable communication between the DMP and Cisco 
StadiumVision Director. 
Because the Cisco StadiumVision Director cannot communicate with DMPs that 
have a later release of the firmware, you cannot use the Management Dashboard to 
load the correct firmware and kernel. Also, DMPDM release 5.2 no longer supports 
the set_param?init.ROOT_disable=0 command. Therefore, you can not ssh 
into the DMP using sysmng or root.