Cisco Cisco StadiumVision Mobile Streamer Release Notes

Page of 47
 
 
© 2010-2011 Cisco Systems, Inc. All rights reserved. 
Page 47 of 47 
To downgrade the firmware and kernel, do the following: 
1.  Enable TAC access via the GUI.   
2.  From SSH, load the appropriate kernel and firmware manually on a per DMP 
basis. 
3.  Once the correct firmware is loaded, use the dashboard to:  
-
  Upgrade the StadiumVision Daemon 
-
  Apply the Global DMP Settings 
See the StadiumVision Video Endpoint (DMP) Design and Implementation Guide for 
more information. 
Note: When you enable TAC access, you are required to set a password (other 
than ‘default’). This password then becomes the ssh password for the DMP. 
Therefore, during this downgrading process remember that your new DMPs will 
have a different userid/password combination from the existing DMPs. After you 
have downgraded the firmware, you can change the password back to default, so 
that all DMPs in the venue have the same login credentials. 
Upgrading DMP 4310Gs 
When using Cisco StadiumVision Director 2.x with DMP 4310Gs, ensure that you 
do the following (in order) via the StadiumVision Management Dashboard: 
  Apply the Initial Config 
  Stop All Video and Flash on the DMP 
 
Upgrade the Firmware
 
 
Restart the Video and Flash on the DMP
 
  Apply Global DMP settings (as needed) 
Note: When you upgrade firmware on the DMP 4310G, the SV Daemon is also 
upgraded. You cannot upgrade the SV Daemon separately on a DMP 4310G. 
See the StadiumVision Video Endpoint (DMP) Design and Implementation Guide for 
more information.