Cisco Cisco 862 MHz GainStar Amplifier Installation Guide
2-2
Installation and Configuration
4034994 Rev B
Before You Begin
The procedures in this chapter assume that you have completed the following:
• Prepared the installation site
• Located the coaxial cable, with or without pin-type coaxial connectors mounted on
• Prepared the installation site
• Located the coaxial cable, with or without pin-type coaxial connectors mounted on
the cable
Required Tools
Before you start, make sure that you have the following tools:
• Torque wrench with a 1/2-inch socket
• Flat-blade screwdriver
• Heavy-duty wire cutters or snips
• Torque wrench set
• Torque wrench with a 1/2-inch socket
• Flat-blade screwdriver
• Heavy-duty wire cutters or snips
• Torque wrench set
Torque Specifications
The following table gives the torque specifications for the Amplifier.
Fastener Torque
Specification
Illustration
Seizure nut
2.0 Nm to 2.8 Nm
Housing Retainer Screws
1.5 Nm to 1.8 Nm
Housing closure bolts
6.8 Nm to 9.0 Nm
Housing plugs test point port plugs 6.8 Nm to 9.0 Nm
RF PG11 to 5/8” adapter
12.0 Nm to 16.0 Nm
Strand clamp mounting bracket
bolts
bolts
6.8 Nm to 9.0 Nm
RF F-Cable Connector
Per manufacturer instructions
HardLine Cable Connector
Per manufacturer instructions