Cisco Cisco Compact EGC Dual Output Amplifier A93270 Data Sheet

Page of 4
 
 
 
 
 
 
Compact Mini Amplifier 93191  
 
 
 
 
Specifications  
 
General Performance 
Units 
93191-x28 
93191-x36 
Notes 
Forward path 
MHz 
40 - 862 
Reverse path 
MHz 
5 - 80 
Gain  
dB 
28 
36 
 
Attenuator, plug-in 
dB 
0 - 18 (in 1 dB steps) 
 
Equalizer, plug-in 
dB 
0 - 18 (in 1 dB steps) 
 
Output tilt   
dB 
0 / 3 / 6 / 9 
 
Number of outputs  
 
Return loss, 5 - 40 MHz 
dB 
20  
 
Return loss, 40 - 862 MHz 
dB 
20 red. 1.5 / octave 
 
Passive reverse loss, with 74069 
dB 
1.8  
 
Output level: CTB 
³ 60 dB, typical 
dBµV 112.0 
Output level: CSO 
³ 60 dB, typical 
dBµV 112.0 
116.5  3 
Noise figure 
dB 
³ 8.5 
³ 7.5 
 
Electrical 
 
 
 
Remote (coax line)    
V AC 
24 - 65
 
 
Power consumption, remote powered 
14.5
 
Current consumption, 24 V AC, fully loaded 
mA 
< 845 
 
Current consumption, 40 V AC, fully loaded 
mA 
< 530
 
 
Current consumption, 60 V AC, fully loaded 
mA 
< 390
 
 
Max. current, input/output 
A AC 
 
 
Hum modulation, at max. current 
dB 
< - 65
 
 
Over-voltage protection 
ms 
2 kV, 1.2  / 50 
 
 
Environmental
 
 
Operating temperature range 
°C 
-20 to + 55 
 
Enclosure category 
 
IP 64
 
 
Mechanical 
 
 
 
Connectors, input 
 
PG11 (5/8”) 
 
Connectors, output and test point 
 
F
 
 
Housing dimensions excl. mounting fittings 
mm 
185 W x 145 H x 95 D
 
 
Emission, EN 50083-2 
dBpW 
< 20 
 
Screening efficiency 
dB 
> 85  
 
Weight 
kg < 
2,2 
 
All specifications are measured with 0 dB link 74089 at the filter connectors. 
 
Notes: 
1) 
Frequency range depends on the diplex filters 
2) 
With plug-in splitter 
3) 
CTB/CSO is measured with 6 dB pre-equalizer, EN 50083-3.2. 
4) 
Exclusive active reverse; for active reverse add 1.5 W