Cisco Prisma II Reverse Optical Receivers Installation Guide

Page of 148
 
Chapter 5        Maintenance and Troubleshooting 
 
 
 
106 
 
Troubleshooting Alarm Conditions 
Module Alarm Conditions 
If the red ALARM indicator is illuminated or is blinking, check the display on the 
front panel to determine the cause of the alarm. 
Alarm 
Function 
Possible Causes 
Possible Solutions 
Rx 1 Optical Input 
Power 
Optical input 1 
 
Broken fiber 
 
Transmitter failure 
 
Check fiber 
 
Transmitter failure 
Rx 2 Optical Input 
Power 
Optical input 2 
 
Broken fiber 
 
Transmitter failure 
 
Check fiber 
 
Transmitter failure 
PsOk 
Bus voltage 
status 
 
Power supply 
faulty 
 
Check power supply 
AGC 1 Range 
Status 
AGC 1 
out-of-range 
alarm 
 
Broken fiber 
 
Transmitter failure 
 
Input power too 
high or too low for 
AGC setting 
 
Check fiber 
 
Transmitter failure 
 
Adjust AGC 
AGC 2 Range 
Status 
AGC 2 
out-of-range 
alarm 
 
Broken fiber 
 
Transmitter failure 
 
Input power too 
high or too low for 
AGC setting 
 
Check fiber 
 
Transmitter failure 
 
Adjust AGC 
 
 
CAUTION: 
Some 1310 nm transmitters with serial numbers beginning with NN are not 
compatible with these receivers. Do not install these transmitters in any daisy 
chain with one or more of these receivers.