Cisco Cisco Prisma II EDR Receiver Data Sheet

Page of 7
Prisma II Ancillary Modules 
 
6
 
 
Prisma II 1310/1550 nm Optical Switches, continued 
 
Specifications 
Optical 
Units 
 
Notes 
Optical Interface 
 SC/APC 
 
 FC/UPC 
 SC/UPC 
 E2000 
 
 
Standard 
Optional 
Optional 
Optional 
 
 
Nominal Optical Wavelength 
nm 
nm 
1310+/- 20 
1550+/-20 
 
Input Optical Power Range 
(standard version)
 
  @ 1550 nm 
  @ 1310 nm 
 
dBm 
dBm 
 
-13 to +18 
-13 to +13 
Input Optical Power Range 
(low input version) 
  @ 1550 nm 
  @ 1310 nm 
 
dBm 
dBm 
 
-30 to 0 
-30 to 0 
Insertion Loss 
dB 
< 2.5 
Cross Talk 
dB 
< -70 
 
Return Loss 
dB 
<-55 dB 
Electrical 
 
 
 
Sense and Switch Time (from Primary to Redundant state) 
ms 
< 50 
Power Consumption 
W DC 
< 5 
Switching Threshold 
dB 
1 – 10 (user changeable) 
 
Restore Threshold 
dB 
0.5 to 9.5 
 
Wait Time before Restoration 
minutes 
0 to 10 in 1 second steps 
 
Environmental 
 
 
 
Temperature Range 
  Full Specs and Operational 
 
°C 
°F 
 
-40 to +65 
-40 to +149 
Humidity Range 
0 to 95 
Mechanical 
 
 
 
Physical Dimensions     
  Depth 
 
in. 
cm 
 
9.8 
24.9 
 
  Width 
in. 
cm 
1.0 
2.5 
 
  Height 
in. 
cm 
7.6 
19.3 
 
  Weight 
lb 
kg 
3.0 
1.4 
 
  Module Width 
slot 
 
 
Notes:  
1. 
Optical input power of -3.0 dBm (-20 dBm for the low input version) or greater is required to maintain the full user-settable threshold 
range.  When the optical input power is less than -3.0 dBm (-20 dBm for low input version) there is a 1-for-1 reduction in threshold range.  
Module will remain in Primary (default) state regardless of Primary input level if Secondary input level is below its switching threshold. 
2. 
Insertion loss of module with 0.5 dB loss per mated connector pair for a total connector loss of 1.0 dB.  Actual loss may be less 
depending on mating connector compatibility. 
3. 
With APC connectors. 
4. 
When operating at ambient temperatures below 0
°C, the power consumption can be up to 15W. 
5. 
Air inlet temperature to Prisma II chassis in non-condensing environment.  Up to 10 minute warm-up time required for start-up below 0
°C 
(32
°F). 
6. 
Recommended for use only in non-condensing environment. 
7. 
On low input version, switching time can be delayed from 0 to 1 second in 50 ms increments.  0 seconds is the default. 
 
 
 
 
 
 
 
Unless otherwise noted, specifications reflect typical performance and are referenced to 68
°F (20°C).  Specifications are based 
upon measurements made in accordance with SCTE/ANSI standards (where applicable), using standard frequency assignments.