Cisco Cisco Prisma II ICIM Data Sheet

Page of 4
Prisma II Forward Optical Receivers 
 
3
 
 
Specifications, continued 
 
Environmental  
Units 
Full Height Single 
Forward Receiver 
High Density 
Forward Receiver 
Notes 
Temperature Range 
     Full Specs 
   
 
    Operational 
 
°C 
°F 
 
°C 
°F 
 
-40 to +65 
-40 to +149 
 
-40 to +65 
-40 to +149 
 
-20 to +65 
-4 to +149 
 
-40 to +65 
-40 to +149 
 
Humidity Range 
0 to 95 
0 to 95 
 
Mechanical 
Units 
Full Height 
Forward Receiver 
High Density 
Forward Receiver 
Notes 
Physical Dimensions 
 
 
 
  Depth 
in. 
cm 
9.8 
24.9 
8.8 
22.4 
 
  Width 
in. 
cm 
1.03 
2.6 
1.03 
2.6 
 
  Height 
in. 
cm 
7.6 
19.3 
3.5 
8.8 
 
  Weight 
lbs 
kg 
2.2 
1.0 
0.9 
0.4 
 
  Module Width 
slots 
1 (full height) 
1 (half height) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note: 
1. Recommended for use only in non-condensing environments.  
 
 
 
Unless otherwise noted, specifications reflect typical performance and are referenced to the ambient air temperature at the inlet to the 
Prisma II chassis.  Specifications are based upon measurements made in accordance with SCTE/ANSI standards (where applicable), using 
standard frequency assignments.