Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide

Page of 140
 
 
Adjusting Alarm Thresholds 
78-4021716-01 Rev C 
71 
 
Adjusting Alarm Thresholds 
To Adjust Alarm Thresholds 
Relative alarm thresholds are both displayed and stored as  relative values. This 
method for adjusting alarm thresholds lets you choose any valid increment size and 
adjust the alarm threshold to any valid value. 
You can use the ICIM to change the adjustable alarm thresholds of this module from 
their factory default values. 
1  At the MODULE menu, press the 
STAT
 key. 
Result: The STATUS menu appears on the ICIM LCD. 
2  Press the 
SEL
 key. The alarm thresholds previously set are displayed. If the 
label n/a is displayed, you cannot configure that alarm threshold. Press the 
 
 
key to highlight the alarm threshold for the next parameter. 
3  When the threshold that you wish to set is highlighted, press the 
ENTER
 key. 
4  Press the 
 
 key or the
 
 key to change the increment size. 
5  Press the 
 
 key or the 
 
 key to adjust the alarm threshold. 
Note: Press the Cancel ( 
ALRM
 ) key to return to the previous menu. 
6  Press the 
ENTER
 key to save the changes. 
Result: Data Saved displays. 