Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide

Page of 184
 
Chapter 2    Module Installation 
 
 
 
20 
78-4025693-01 Rev D 
Cleaning Optical Connectors 
Introduction 
Cleaning fiber-optic connectors can help prevent interconnect problems and 
therefore aid system performance.  When optical connectors are disconnected and 
reconnected, the fiber surface can become dirty or scratched.  The goal of cleaning 
the fiber optic connectors is to remove all dust and contaminants without leaving 
any residue.  It is also recommended that all connectors be visually inspected after 
cleaning to verify the connector is clean and undamaged. 
 
Recommended Equipment 
 
CLETOP or OPTIPOP ferrule cleaner (for specific connector type) 
 
Compressed air (also called “canned air”) 
 
Lint-free wipes moistened with optical-grade (99%) isopropyl alcohol 
 
Bulkhead swabs (for specific connector type) 
 
Optical connector scope with appropriate adaptor 
 
Tips for Optimal Fiber Optic Connector Performance 
 
Do not connect or disconnect optical connectors with optical power present. 
 
Always use compressed air before cleaning the fiber optic connectors and when 
cleaning connector end caps. 
 
Always install or leave end caps on connectors when they are not in use. 
 
If you have any degraded signal problems, clean the fiber optic connector. 
 
Advance a clean portion of the ferrule cleaner reel for each cleaning. 
 
Turn off optical power before making or breaking optical connections to avoid 
microscopic damage to fiber mating surfaces.