Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide
Chapter 3 Operation Using CLI
58
78-4025693-01 Rev D
Disabling Paging
Normally, when a CLI response is too long to fit in a single 24-line Telnet window,
Normally, when a CLI response is too long to fit in a single 24-line Telnet window,
the output is automatically paged using the familiar “more” format, as shown in the
following example:
CLI> module modid * show control * exit
MODID NAME SETTING UNITS
20/05 Enable 1
20/05 CwMode 0
20/05 LoRFInh 0
20/05 Master Slave (0)
20/05 RFDrive 0 dB
20/06 Enable 1
20/06 Master 1
20/06 WaveLen 1550nm (1)
20/06 NomPin 0 dBm
20/07 Enable 1
20/07 CwMode 1
20/07 LoRFInh 1
20/07 Master Master (1)
20/07 RFDrive 0 dB
20/08 Cross False (0)
20/08 Bar False (0)
20/08 Mode Auto (1)
20/08 WaveLen 1550nm (1)
20/08 NomPIn3 0 dBm
20/08 NomPIn4 0 dBm
20/08 Delta 6 dB
20/08 HystAmpl 3 dB
---line 23 of 51 total lines--Enter 'Q' to quit:
Craft operators can simply press Enter to display the next page of output. However,
network management software may have difficulty working with this output
format.