Chapter 4    Operation Using ICIM 
 
 
 
84 
78-4025693-01 Rev D 
Checking Alarms using the ICIM 
To Check Alarms using the ICIM 
Alarms fall into one of the following categories. 
 
Major low 
 
Minor low 
 
Minor high 
 
Major high 
If the red ALARM LED on the front panel is blinking, a minor alarm condition is 
indicated. If the ALARM LED on the front panel is illuminated, a major alarm 
conditions is indicated. 
1  From the MAIN menu, press the 
 key to highlight the Shelf and Slot fields 
2  Press the 
 key to address the Shelf number. Then press the 
 key or the 
 keys to scroll to the number of the desired shelf.     
3  Press the 
 key. 
Result:  The Slot field is highlighted. 
4  Press the 
 key or the 
 key to scroll to the number of the desired slot.  
5  Press the 
 key. 
Result:  The MODULE menu appears on the ICIM LCD. 
6  Press the 
 key. 
Result:  Module alarm conditions display. 
7  Use the 
 key or the 
 key to scroll through alarm conditions until the 
desired alarm is displayed. 
8  Monitor the alarm condition(s). Take appropriate action. Verify that all settings 
and thresholds relating to the alarm indication are set correctly to rule out an 
unintended alarm.  
9  When finished, press the 