Troubleshooting Alarm Conditions 
Amplifier Alarm Conditions 
If the red ALARM indicator is illuminated or is blinking, check the ICIM2 display to 
determine the cause of the alarm. 
Alarm 
Parameter 
Possible Causes 
Possible Solutions 
LasBias 
Laser current 
Internal problem 
Contact Customer Service 
for assistance. 
InPwr 
Optical input 
Dirty or loose connector 
Low input 
Check input source. 
OutPwr 
 
Optical output 
 
Low input 
Internal problem 
Check input. 
Contact Customer Service 
for assistance. 
Module disabled 
Enable module. 
LasTemp 
Laser temperature  Internal problem 
Fan Tray failure 
Ambient temperature 
Chassis air filter requires 
changing 
Contact Customer Service 
for assistance. 
IntPs 
Input power 
supply 
Internal problem 
Contact Customer Service 
for assistance.