Chapter 3    Operation Using CLI 
 
 
 
42 
78-4025693-01 Rev D 
The following sample dialog illustrates the use of these arguments. 
*/* MODULE> show alarmparam *pwr minorhigh <Enter>
 
  MODID  NAME      MinorHigh
 
  20/05  OutPwr    1
 
  20/06  InPwr     5
 
  20/06  MaxInPwr  N/A
 
SUCCESS!
 
*/* MODULE>
 
Note: 
 
The returned value of N/A shown above indicates that the alarm does not have 
the requested parameter. 
 
Some alarm values can also be changed by a craft operator or network 
management system. See the set alarmparam command for details. 
Show Module 
This command is used to generate a list of information for specified modules that 
will help with their physical identification. 
The following is a sample craft operator dialog using show module to display 
information for the modules in slots 3, 4, and 5 of all chassis in the ICIM domain: 
*/* MODULE> slot [3-5] <Enter>
 
*/[03-05] MODULE> show module <Enter>
 
  MODID  MODTYPE      NAME                       SERIAL
 
  20/03  Prisma II    Power Supply 3 / Fan Tray  ^ABCDEFG
 
  20/05  9x19dBm      Prisma II Hybrid Amp       ^AAG1AZI
 
SUCCESS!
 
*/[03-05] MODULE>
 
 
Info Command 
The info command (at the Module prompt) is used to display more detailed 
information than is returned by using the show command. The command can be 
followed by the argument controlmonitoralarm, or module, which, in turn, is 
followed by one or more arguments further specifying the type of information to be 
returned. 
The details or characteristics that can be requested for each argument include the 
following: 
Argument 
Details 
Description 
Alarm 
 
Hysteresis 
threshold hysteresis value 
Index 
alarm number, starting at 1, in the list of alarms 
Label 
name of the alarm 
Limitadjust 
allowed if alarm is adjustable, not allowed if not 
Majorhigh 
High Major threshold