Cisco Cisco Prisma II ICIM 2 Installation Guide

Page of 184
 
 
 
Module Commands 
 
78-4025693-01 Rev D 
41 
 
  MODID  NAME    VALUE     UNITS
 
  20/05  OutPwr  8.29224   dBm
 
  20/06  InPwr   5.91542   dBm
 
  20/06  OutPwr  18.9929   dBm
 
  20/13  InPwr   17.2202   dBm
 
  20/13  OutPwr  19.4671   dBm
 
SUCCESS!
 
*/* MODULE>
 
Note: 
 
The information returned by the monitor argument includes units of 
measurement. 
 
InPwr values are stated to several decimal places, but only the first 2 or 3 are 
significant. 
Show Alarmstate 
The following sample dialog shows the kind of information returned by the 
alarmstate argument. 
*/* MODULE> show alarmstate *pwr <Enter>
 
  MODID  NAME      STATE
 
  20/05  OutPwr    0 (major low)
 
  20/06  InPwr     0 (major low)
 
  20/06  MaxInPwr  0 (ok)
 
  20/07  OutPwr    2 (ok)
 
  20/08  XSPwr     0 (ok)
 
  20/13  OutPwr    0 (major low)
 
  20/13  InPwr     0 (major low)
 
SUCCESS!
 
*/* MODULE>
 
Note: The information returned by the alarmstate argument provides both the 
numeric value and its meaning. 
Show Alarmparam 
Alarms also have parameters, such as thresholds. Accordingly, the alarmparam 
argument is in turn followed by an argument that specifies one of five parameters: 
hysteresismajorhighmajorlowminorhigh, and minorlow