Cisco Prisma II Reverse Optical Receivers Installation Guide
Chapter 3 Operation Using CLI
44
78-4025693-01 Rev D
Argument
Details
Description
Downldable
module can be downloaded with new firmware
Inactiverev
inactive software image revision for the module
Mandata
manufacturing data
Modtype
manufacturing data (alias for MANDATA)
Name
name of module
Nextimage
flash bank where active image resides
Numanalogcontrols number of analog controls
Numcontrols
Numcontrols
total number of controls
Numdigitalcontrols
number of digital controls
Nummonits
number of monitored values
Numofalarms
number of alarms
Scriptrev
script revisions
Selftest
status of module self test
Serial
serial number
Tos
time of service
The following sample dialog illustrates the use of the info command to view the
value and statenames characteristics for the cross control:
*/* MODULE> info control cross value statenames <Enter>
MODID NAME VALUE STATENAMES
20/08 Cross False (0) False (0), True (1)
SUCCESS!
*/* MODULE>
In the example above, the control's name pattern was explicit (no wildcards). The
details to be listed were Value and the available StateNames (not all controls and
monitors have StateNames). In this case, the value is 0 (False).