Cisco Prisma II Reverse Optical Receivers Installation Guide

Page of 184
 
Chapter 3    Operation Using CLI 
 
 
 
44 
78-4025693-01 Rev D 
Argument 
Details 
Description 
Downldable 
module can be downloaded with new firmware 
Inactiverev 
inactive software image revision for the module 
Mandata 
manufacturing data 
Modtype 
manufacturing data (alias for MANDATA) 
Name 
name of module 
Nextimage 
flash bank where active image resides 
Numanalogcontrols  number of analog controls 
Numcontrols 
total number of controls 
Numdigitalcontrols 
number of digital controls 
Nummonits 
number of monitored values 
Numofalarms 
number of alarms 
Scriptrev 
script revisions 
Selftest 
status of module self test 
Serial 
serial number 
Tos 
time of service 
The following sample dialog illustrates the use of the info command to view the 
value and statenames characteristics for the cross control: 
*/* MODULE> info control cross value statenames <Enter>
 
  MODID  NAME   VALUE      STATENAMES
 
  20/08  Cross  False (0)  False (0), True (1)
 
SUCCESS!
 
*/* MODULE>
 
In the example above, the control's name pattern was explicit (no wildcards). The 
details to be listed were Value and the available StateNames (not all controls and 
monitors have StateNames). In this case, the value is 0 (False).