Cisco Prisma II Reverse Optical Receivers Installation Guide

Page of 184
 
 
 
Module Commands 
 
78-4025693-01 Rev D 
47 
 
This response shows that the OutPwr, LasTemp, LasBias, and InPwr alarms all have 
majorlow and majorhigh parameters. However, only InPwr, OutPwr, and LasBias 
can be changed, as LasTemp is of type 3 rather than 1, 2, or 7. 
The following sample dialog shows how a craft operator would set the majorhigh 
parameter of outpwr to 35°C, and then confirm the change. 
20/06 MODULE> set alarmparam outpwr majorhigh 35 <Enter>
 
SUCCESS!
 
20/06 MODULE>
 
20/06 MODULE> info alarm * type majorhigh
 
  MODID  NAME     TYPE MAJORHIGH
 
  20/06  PsOk     6    N/A
 
  20/06  OutPwr   1    35
 
  20/06  IntPs    6    N/A
 
  20/06  Enable   6    N/A
 
  20/06  LasTemp  3    15
 
  20/06  LasBias  1    -0.01
 
  20/06  InPwr    1    25
 
  20/06  Service  5    N/A
 
SUCCESS!
 
20/06 MODULE>