Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 47
78-715189-01 Rev C 
Operation 
3-3 
Operating the HEDA, 
Continued
 
Verifying RF Output 
It is important to make sure that RF output is within the desired range before you 
adjust the variable pad and equalizer. Otherwise, the HEDA will not operate 
properly.  
Follow the procedure below to verify the RF output of the HEDA. 
1. 
On the back of the chassis, locate the port for RF output used by the amplifier.  
Note: Output connectors are on Port B row. 
2. 
Using a 7/16-in. open-end wrench, disconnect the RF cable designated for the 
RF output of the amplifier and connect a test cable from the RF output 
connector to a spectrum analyzer. Torque the connector to the specifications 
given by the connector manufacturer. Do not over tighten
3. 
Measure output level of the amplifier for the lowest carrier level. 
4. 
Verify that when the variable pad is set to 0, the RF output level of the 
amplifier is within +3 dBmV of the desired input level of the device being fed. 
 
IF the amplifier RF output is . . .  THEN . . .  
within +3 dBmV of the desired 
record this value in your  
transmitter input level 
Maintenance Log. Refer to the sample 
 
Maintenance Log in appendix A.  
more than +3 dBmV of the 
refer to the appropriate section in 
desired transmitter input level 
Chapter 4 for assistance in 
 
 
troubleshooting. 
less than the desired input level  refer to the appropriate section in
 
Chapter 4 for assistance in 
 
troubleshooting. 
 
5. 
Go to the next procedure, Ensuring Proper Signal Strength and Adjusting 
the Selectable Pad