Cisco Cisco Prisma II ICIM Installation Guide

Page of 47
3-4 
Operation 
78-715189-01 Rev C 
Ensuring Proper Signal Strength and Adjusting the Selectable Pad 
Variable Pad Adjustment Procedure 
Important:The following procedure assumes that you have verified the RF output 
and that the selectable pad is set to 0. 
To adjust the HEDA signal strength so that it meets the input requirements of the 
device being fed, you may need to add attenuation to the input signal. Otherwise, 
the amplifier will not operate properly. To ensure proper signal strength, follow 
these steps. 
1. 
Check that the selectable pad is set to 0. 
2. 
Compare the actual RF output level obtained in the previous procedure to the 
optimal input level required by the device to which the signal is being routed. 
 
If the actual level is . . . 
Then . . . 
within ±0.5 dB of the 
go to the next procedure, Ensuring  
optimal level 
 a Flat Output Signal by Adjusting the  
 
 
Variable Equalizer. 
more than 0.5 dB of the  
increase the input attenuator pad.  
optimal level  
Refer to the next step. 
less than 0.5 dB of the  
refer to the appropriate section in  
optimal level 
 Chapter 5 for assistance in troubleshooting.  
 
3. 
Using a 1/8-in. flat-blade screwdriver, turn the pad setting on the front panel 
of the amplifier so the attenuation is correct for your operation. Refer to the 
following table.
 
 
 
 
 
 
Pad Setting  
Amount of Attenuation 
 
0 dB 
 
1 dB 
 
2 dB 
 
3 dB 
 
4. 
Once you have set the pad correctly, adjust the step equalizer to ensure a flat 
output signal. Refer to the following procedure, Ensuring a Flat Output 
Signal by Adjusting the Step Equalizer