Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 106
3-20 
Operation Using the ICIM 
78-713378-01 Rev C 
Checking Reverse Receiver Alarms Using the ICIM, 
Continued
 
User Alarm Data Display 
The user alarm data for this module is shown below. For additional troubleshooting 
information, see Chapter 5, Maintenance and Troubleshooting.  
 
Alarm  
Function 
Major 
Low 
Limit 
Minor 
Low 
Limit 
Minor 
High 
Limit 
Major 
High 
Limit  Hysteresis  Operating Range 
InPwr1 
Optical 
input 1 
-20.0 
-4.0 
2.0 
3.2 
-17.0 to +2.0 dBm  
InPwr2 
Optical 
input 2 
-20.0 
-4.0 
2.0 
3.2 
-17.0 to +2 dBm  
ModTemp  Module 
Temp 
-125 
-85 
85 
125 
-40°C and 65°C  
 
User Alarm Menus 
After a module’s ALARM function is selected, press the 
 
 key or the
 
 key to 
scroll through active alarms.  Some typical user ALARMS screens are shown below. 
 
 
 
 
 
 
 
 
 
 
 
 
 