Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 106
5-4 
Maintenance and Troubleshooting 
78-713378-01 Rev C 
Troubleshooting Alarm Conditions 
Alarm Conditions
 
If the red ALARM indicator is illuminated or is blinking, check the display on the 
front panel to determine the cause of the alarm.  
 
Alarm 
Function 
Possible Causes 
Possible Solutions 
PIndBm1 
Optical input 1 
Broken fiber 
Check fiber 
PIndBm2 
Optical input 2 
Transmitter failure 
Check Transmitter 
TempC 
Module 
Temperature 
Ambient 
temperature is too 
high due to: 
 
 
 
• 
Air conditioner 
malfunction. 
Diagnose the problem and 
repair or replace as needed. 
 
 
• 
Airflow through 
the rack 
restricted or cut 
off. 
Ensure the airflow system has 
not been damaged or removed. 
Repair or replace as needed. 
 
 
• 
Fan Tray cooling 
fans are not 
operating 
properly. 
Troubleshoot the fans. 
Telephone Cisco Services for 
help. 
PsOk 
Bus voltage 
status 
Power supply faulty  Check power supply