Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide

Page of 106
78-713378-01 Rev C 
Operation Using the ICIM 
3-19 
Checking Reverse Receiver Alarms Using the ICIM 
Checking Alarms 
If the red ALARM LED on the front panel is blinking a minor alarm condition is 
indicated. If the red ALARM LED on the front panel is illuminated, a critical alarm 
conditions is indicated. 
Alarms fall into one of the following categories. 
• 
Major low 
• 
Minor low 
• 
Minor high  
• 
Major high 
To check alarm conditions follow these steps. 
 
1. 
From the MAIN menu, press the 
 
 key to highlight the Shelf and Slot 
fields.  
2. 
Press the 
SEL
 key to address the Shelf number. Then press the 
 
 key or 
the 
 keys to scroll to the number of the desired shelf.      
3. 
Press the 
ENTER
 key. The Slot field is highlighted. 
4. 
Press the 
 
 key or the 
 key to scroll to the number of the desired slot.   
5. 
Press the 
ENTER
 key.  The MODULE menu is displayed on the ICIM. 
6. 
Press the 
ALRM
 key. The module alarm conditions are displayed here. 
7. 
Use the 
 
 key or the 
 
 key to scroll through alarm conditions until the 
desired alarm is displayed. 
8. 
Monitor the alarm condition(s). Take appropriate action. Verify that all 
settings and thresholds relating to the alarm indication are set correctly to 
rule out an unintended alarm. 
9. 
When finished, press the 
MAIN
 key. The display returns to the MAIN menu. 
 
Continued on next page