Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide
4-22
Operation Using LCI
78-713378-01 Rev C
Configuring the Reverse Receiver
Introduction
Using LCI, you can configure the parameters listed below.
Configurable Parameters
Configurable parameters for the Prisma II Reverse Receiver are listed below.
Control
Function
Values
Default
Rx 1 Mute
Switch,
Rx 2 Mute
Switch
Force Mute. Muting of the RF signal and
removal of power to the amplifier only if the
Enable control is on for this particular side.
On = Mute On
Off = Mute Off
Off
Rx 1 Receiver
Enable,
Rx2 Receiver
Enable
Enables or disables unit operation, i.e.,
muting enabled and no alarm capability.
On = Enabled
Off = Disabled
On
Rx 1 Manual
Alarm
Rx 2 Manual
Alarm
Force Alarm. Alarm relay is manually
overridden only if the Enable control is On.
This sets a particular side to alarm as if there
was an internal alarm, i.e., Alarm output
high, muting on as per Force Mute above
On = Alarm On
Off = Alarm Off
Off
Rx 1 Master
Select
Rx 2 Master
Select
Configures the module as master or slave. If
set to Master, the unit is controlled only by
the Enable control above. If set to Slave, the
unit is controlled by a combination of the
Enable control and the external input
CNT_IN_1 or CNT_IN_2.
On = Master On
Off = Slave On
On
Rx 1
Attenuator
Rx 2
Attenuator
Sets the attenuation level of the output RF
signal.
Decimal number
between 0 and 20
dB, increments of
0.5 dB
0