4-22 
Operation Using LCI 
78-713378-01 Rev C 
Configuring the Reverse Receiver 
Introduction 
Using LCI, you can configure the parameters listed below.  
Configurable Parameters  
Configurable parameters for the Prisma II Reverse Receiver are listed below. 
 
 
Control  
Function 
Values 
Default 
Rx 1 Mute 
Switch, 
Rx 2 Mute 
Switch 
Force Mute.  Muting of the RF signal and 
removal of power to the amplifier only if the 
Enable control is on for this particular side.  
On = Mute On 
Off = Mute Off 
Off 
Rx 1 Receiver 
Enable, 
Rx2 Receiver 
Enable 
Enables or disables unit operation, i.e., 
muting enabled and no alarm capability. 
On = Enabled 
Off = Disabled 
On 
Rx 1 Manual 
Alarm 
Rx 2 Manual 
Alarm 
Force Alarm.  Alarm relay is manually 
overridden only if the Enable control is On. 
This sets a particular side to alarm as if there 
was an internal alarm, i.e., Alarm output 
high, muting on as per Force Mute above 
On = Alarm On 
Off = Alarm Off 
Off 
Rx 1 Master 
Select 
Rx 2 Master 
Select 
Configures the module as master or slave. If 
set to Master, the unit is controlled only by 
the Enable control above. If set to Slave, the 
unit is controlled by a combination of the 
Enable control and the external input 
CNT_IN_1 or CNT_IN_2. 
On = Master On 
Off = Slave On 
On 
Rx 1 
Attenuator 
Rx 2 
Attenuator 
Sets the attenuation level of the output RF 
signal. 
Decimal number 
between 0 and 20 
dB, increments of 
0.5 dB