Cisco Cisco Prisma II ICIM Installation Guide

Page of 139
78-748705-01 Rev C 
Installation 
2-27 
 
Master/Slave Connections, 
Continued
 
Typical Master/Slave Jumper Connections for Modules in Separate Chassis 
Important:  Each chassis that is used for alarm connections must have a separate, dedicated interface panel. 
The diagram below shows jumper connections for a typical master/slave connection between two modules in separate 
chassis.  The master module is shown in chassis 1, slot 4 and the slave module is in chassis 2, slot 6.  If a critical fault occurs in 
the master module, its relay signal is carried via the jumpers, from the chassis 1, slot 4 ALARM OUT terminal to the chassis 2, 
slot 6 ALARM IN terminal.  This turns on the slave module located in chassis 2, slot 6.  The slave module continues in 
operation until the master module is fixed.  At that time, the master module automatically takes over and the slave module 
switch relay turns off.