Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide

Page of 139
78-748705-01 Rev C 
Installation 
2-21 
Interface Panel Features 
Introduction 
This section describes the various features of the Prisma II Redundancy Interface 
Panel. 
Chassis Slot Numbers 
The Prisma II Chassis has sixteen slots.  Each chassis slot has two alarm outputs and 
two alarm inputs.  Slot numbers and the corresponding outputs and inputs are 
represented and labeled just below the terminal strips on the front of the Prisma II 
Redundancy Interface Panel.   
 
Note:  Slot 1 of the chassis is always reserved for the power supply and has no 
terminals on the panel.  Slot 3 is represented on the interface panel, but is reserved 
for the fan tray.  Therefore, the interface panel’s slot 3 spring terminals can only be 
used as alarm outputs or inputs for the fan tray. 
Terminals Strips 
The front of the interface panel has four terminal strips that house spring terminals 
for each slot.  The two left-side strips house two ALARM OUT terminals for each of 
the chassis slots 2 through 16, and the two right-side strips house two ALARM IN 
terminals for each of the chassis slots 2 through 16.   
Spring Terminals  
The spring terminals are the points where the actual hard-wire connections between 
modules are made.  Each spring terminal on the interface panel is an extension of a 
pin on the ALARMS OUT and ALARMS IN connectors on the chassis.  Pressing the 
bottom lever of the spring terminal allows insertion of a jumper wire into the hole of 
the terminal.  Releasing the lever secures the wire to the terminal. 
Alarm Terminal Designations 
The ALARM OUT and ALARM IN terminal strips, chassis slot numbers, and  
A/B spring terminals are labeled just below the terminal strips on the front of the 
interface panel.