Operation Using the ICIM 
3-27 
Check Processor Alarms Using the ICIM 
Introduction 
The ICIM allows you to check processor alarms. 
ALARMS Display 
The table below shows the alarm data available for the processor.   
 
Alarm  
Alarm Condition 
Indication 
Possible Cause 
DCPower 
Status of +24V 
input, -5V input, 
1.8V regulator, and 
3.3V regulator. 
Fault 
Check the fan try to see if 
the power supplies are 
working.  Make sure the 
module is fully seated in 
the chassis.  Check 
VDC1_8 and VDC3_3 
monitor to see if either 
voltage is out of spec. due 
to a bad regulator. 
OSM_Comm  Gets set when it is 
not possible to read 
and write to the 
EEPROM in an 
installed OSM. 
Fault 
Ensure transmitter is fully 
seated.  Remove and 
reinstall transmitter.   
FPGA1 
Indicates that 
FPGA1 can be read 
and written to. 
Fault 
Hardware failure. 
Clock1 
Alarms when the 
100 MHz or 125 
MHz clock has lost 
lock in transmitter 1. 
Fault 
Check Clk100_1 and 
Clk125_1 monitors to see 
which clock is lost.  Ensure 
module Clk_Src has not 
been accidentally set to 
Slave.  If in Slave mode, 
make sure there is a valid 1 
MHz reference present. 
Las1Pres 
Transmitter 1 is 
missing.   
Fault 
Ensure transmitter 1 is 
installed and fully seated. 
Las1EOL 
Laser 1 is near end 
of life.   
Fault 
Time to replace 
transmitter.