Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 139
78-748705-01 Rev C 
Installation 
2-19 
Alarm I/O Connections,
 Continued 
 
Chassis 
Slot 
ALARMS OUT 
Pin # 
Backplane 
Name 
Function 
11 
11 
CNT_OUT11_1  Alarm state 
30 
CNT_OUT11_2  Module dependent 
12 
12 
CNT_OUT12_1  Alarm state 
31 
CNT_OUT12_2  Module dependent 
13 
13 
CNT_OUT13_1  Alarm state 
32 
CNT_OUT13_2  Module dependent 
14 
14 
CNT_OUT14_1  Alarm state 
33 
CNT_OUT14_2  Module dependent 
15 
15 
CNT_OUT15_1  Alarm state 
34 
CNT_OUT15_2  Module dependent 
16 
16 
CNT_OUT16_1  Alarm state 
35 
CNT_OUT16_2  Module dependent 
N/A 
1, 17, 18, 19, 
20, 36, 37 
Not used 
N/A 
 
Notes:   
• 
Return path for all connections is chassis ground 
• 
Alarm state indications: 
− 
Normal (with module installed): closed to ground 
− 
Critical alarm (or module not installed): open to ground 
• 
Alarm relay rating: 2A 30 V DC (resistive)