Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 139
3-22 
Operation Using the ICIM 
78-748705-01 Rev C 
Configure the Processor Using the ICIM 
Introduction 
The ICIM allows you to configure parameters for the processor. 
CONFIG Parameters  
The table below shows configurable parameters for the processor. 
 
Parameter 
Function 
Values 
Default 
Clk_Src 
Controls the reference clock input. 
• 
Indpend:  The transmitter 
generates its own clock signal 
but does not send it outside the 
processor. 
• 
Master:  The transmitter 
generates its own clock signal. 
• 
Slave:  Uses the clock from a 
different processor.  If a clock is 
not present, alarms are 
generated. 
• 
Indpend 
• 
Master 
• 
Slave 
Indpend 
Tx_1 
Mutes all alarms except for 
Las1Bias on an idle transmitter.  
The Las1Bias alarm will alert the 
operator if the transmitter is 
present but disabled. 
Should be set to Idle only if the 
module is not being used.  Will 
mute the alarms but will not 
disable the laser. 
Active or Idle 
Active  
NoisSup1 
Controls whether transmitter 1 
noise suppression is On or Off. 
On or Off 
Off 
Laser1 
Enables or disables transmitter 1 
laser.  If Enable, the laser is on.  If 
Disable, the laser for this 
transmitter is forced off.   
Enable/Disable  Enable