Cisco Cisco Prisma II EDR Receiver Installation Guide
3-22
Operation Using the ICIM
78-748705-01 Rev C
Configure the Processor Using the ICIM
Introduction
The ICIM allows you to configure parameters for the processor.
CONFIG Parameters
The table below shows configurable parameters for the processor.
Parameter
Function
Values
Default
Clk_Src
Controls the reference clock input.
•
•
Indpend: The transmitter
generates its own clock signal
but does not send it outside the
processor.
•
Master: The transmitter
generates its own clock signal.
•
Slave: Uses the clock from a
different processor. If a clock is
not present, alarms are
generated.
•
Indpend
•
Master
•
Slave
Indpend
Tx_1
Mutes all alarms except for
Las1Bias on an idle transmitter.
The Las1Bias alarm will alert the
operator if the transmitter is
present but disabled.
Should be set to Idle only if the
Should be set to Idle only if the
module is not being used. Will
mute the alarms but will not
disable the laser.
Active or Idle
Active
NoisSup1
Controls whether transmitter 1
noise suppression is On or Off.
On or Off
Off
Laser1
Enables or disables transmitter 1
laser. If Enable, the laser is on. If
Disable, the laser for this
transmitter is forced off.
Enable/Disable Enable