Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 139
3-30 
Operation Using the ICIM 
78-748705-01 Rev C 
Check Processor Alarms Using the ICIM,
 Continued 
Checking Alarms 
If the red ALARM LED on the processor is blinking, a minor alarm condition is 
indicated.  If the red ALARM LED on the front panel is illuminated, a critical alarm 
condition is indicated. 
Alarms fall into one of the following categories. 
• 
Major low 
• 
Minor low 
• 
Minor high  
• 
Major high 
Follow these steps to check alarm conditions. 
 
1. 
From the MAIN menu, press the 
 
 key to highlight the Shelf and Slot 
fields.   
2. 
Press the 
SEL
 key to address the Shelf number.  Then press the 
 
 key or 
the 
    
 keys to scroll to the number of the desired shelf.   
3. 
Press the 
ENTER
 key. 
Result:  The Slot field is highlighted. 
4. 
Press the 
 
 key or the 
    
 key to scroll to the number of the desired slot.   
5. 
Press the 
ENTER
 key. 
Result:  The MODULE menu is displayed on the ICIM. 
6. 
Press the 
ALRM
 key. 
Result:  The module alarm conditions are displayed. 
7. 
Use the 
 
 key or the 
 
 key to scroll through alarm conditions until the 
desired alarm is displayed. 
8. 
Monitor the alarm condition(s) and take appropriate action.  Verify that all 
settings and thresholds relating to the alarm indication are set correctly to 
rule out an unintended alarm. 
9. 
When finished, press the 
MAIN
 key. 
Result:  The display returns to the MAIN menu.