Cisco Cisco Prisma II ICIM Technical References
Prisma II Transmitter Does Not
Respond to ICIM "Update Adr"
Command Technical Bulletin
Respond to ICIM "Update Adr"
Command Technical Bulletin
Overview
Purpose
The purpose of this technical bulletin is to inform Prisma II™ transmitter users of
a possible symptom where the transmitter does not respond to the ICIM "Update
Adr" command, and explain how to resolve that symptom should it occur.
Audience
This technical bulletin applies to all system engineers and managers who are
responsible for operating and/or maintaining Cisco Prisma II equipment.
Affected Units
A few customers may experience this symptom if they have the following Prisma
II transmitters with serial numbers beginning with "MM":
High Density Transmitter (HDTx) - manufactured on or before April 2006
(date code D06)
Full Height 1310 nm Forward Transmitter - manufactured on or before May
2006 (date code E06)
Full Height 1550 nm Forward Narrowcast Transmitter - manufactured on or
before May 2006 (date code E06)