Cisco Prisma CWDM Filters Data Sheet

Page of 5
 
 
 
 
 
 
 
 
 3
  
 
CWDM Passives  
for 16-Channel CWDM HFC Architectures 
 
 
 
Specifications  
 
CWDM LGX-Compatible 4-Channel MUX/DMUX 
Parameters 
Units 
4-Channel Low band 
4-Channel High band 
Notes 
Center Wavelengths 
nm 
1271, 1291, 1311, 1331 
1511, 1531, 1551, 1571 
 
Module Dimensions 
 
 
 
 
Depth (max) 
cm/in 
15.9 / 6.26 
 
Width 
cm/in 
2.9 / 1.15 (1 LGX slot) 
 
Height cm/in 
10.2 
4.0 
 
Faceplate Height   
cm/in 
13.0 / 5.1 
 
Common Specifications 
 
 
 
Channels  
 
Bandwidth per Channel @ - 0.5 dB 
nm 
> 13,5  
> 14 @ 1511 and 1531 
> 15 @ 1551 and 1571 
 
Pass Band Ripple 
dB 
< 0.5 
 
Isolation 
 
 
 
@ adjacent channel 
dB 
> 30 
 
@ non-adjacent channel 
dB 
> 40 
 
Insertion Loss 
 
 
@ 4 channels 
dB 
< 2.5 
 
Directivity dB 
50 
 
Return Loss 
dB 
> 50 
 
Operating Temperature 
°C 
-15 to +70 
-40 to +85 
 
Connector 
 
SC/APC or E2108 
 
Notes: 
1)  Losses include input/output and common connector losses 
2)  With 0.5 dB additional insertion loss 
Recommended for use in non-condensing environments only 
 
CWDM LGX-Compatible 8-Channel MUX/DMUX 
Parameters 
Units 
8-Channel Low band  
8-Channel High band 
Notes 
Center Wavelengths 
nm 
1271, 1291, 1311, 1331 
1351, 1371, 1431, 1451 
1471, 1491, 1511, 1531 
1551, 1571, 1591, 1611 
 
Module Dimensions 
 
 
 
 
Depth (max) 
cm/in 
15.9 / 6.26 
 
Width 
cm/in 
5.8 / 2.3 (2 LGX slot) 
 
Height cm/in 
10.2 
4.0 
 
Faceplate Height   
cm/in 
13.0 / 5.1 
 
Common Specifications 
 
 
 
Channels  
 
Bandwidth per Channel @ - 0.5 dB 
nm 
> 13,5 
> 14 @ 1471 - 1531 
> 15 @ 1551 - 1571 
 
Pass Band Ripple 
dB 
< 0.5 
 
Isolation 
 
 
 
@ Adjacent channel 
dB 
> 30 
 
@ Non-adjacent channel 
dB 
> 40 
 
Insertion Loss 
 
 
@ 8 channels 
dB 
< 3.0 
 
Directivity dB 
50 
 
Return Loss 
dB 
> 50 
 
Operating Temperature 
°C 
-15 to +70 
-40 to +85 
 
Connector 
 
SC/APC or E2108 
 
Notes: 
1)  Losses include input/output and common connector losses 
2)  With 0.5 dB additional insertion loss 
Recommended for use in non-condensing environments only