Cisco Prisma CWDM Filters Data Sheet

Page of 3
Prisma Singlemode Multiband Couplers/Splitters 
 
2
 
 
Specifications 
 
Description 
Units 
Common Specifications 
Notes 
Center Wavelengths 
nm 
1310 & 1550 
 
Bandpass nm 
± 20 @ 1310 and 1550 
 
Fiber Type 
(unconnectorized only) 
 
Single mode, 250 
µm bare fiber 
 
Operating Temperature 
°C / °F 
-5 to +65 / +23 to +149 
 
Storage Temperature 
°C / °F 
-40 to +85 / -40 to +185 
 
Directivity dB 
≥ 55 
 
Optical Return Loss 
    Unconnectorized 
    SC/UPC connector 
    SC/APC connector 
 
dB 
dB 
dB 
 
≥ 55 
≥ 55 
≥ 60 
 
Physical Dimensions 
 
 
 
 
Packaged and Connectorized 
  LGX-compatible modules 
     Faceplate 
          Height 
          Width 
     Coupler Enclosure 
          Height 
          Width 
     Overall Depth 
 
  Rack Mount 
     Height 
     Width 
     Depth 
 
 
 
 
mm / in. 
mm / in. 
 
mm / in. 
mm / in. 
mm / in. 
 
 
mm / in. 
mm / in. 
mm / in. 
(maximum unless otherwise specified) 
 
 
1-Wide*             2-Wide**          3-Wide*** 
130.5/5.14         130.5/5.14       130.5/5.14 
29.26/1.15        59.26/2.33       89.26/3.51 
 
98.5/3.88          98.5/3.88         98.5/3.88 
26.52/1.04        56.52/2.23       86.51/3.41 
127.51/5.02     127.51/5.02      127.51/5.02 
 
1 RU (1x32)             2 RU (1x64) 
44.5/1.75                88.1/3.47 
482.6/19                 482.6/19 
304.8/12                 304.8/12 
 
Packaged and Unconnectorized 
  1x2 componen
    Diameter 
    Length 
 
 
mm / in 
mm / in. 
 
 
3.0/0.12 
55/2.17  
 
 
* 1-wide LGX module includes 1x2, 1x2 dual, 2x2, 2x4, 1x3, 1x4, 1x5 couplers/splitters 
 
** 2-wide LGX module includes 1x6, 1x7, 1x8, 1x10 couplers/splitters 
 
*** 3-wide LGX module includes 1x12, 1x16 couplers/splitters