Cisco Cisco OptoStar II Driver Amplifier Installation Guide
Starting up the Module, Continued
•
A DB meter or spectrum analyzer can be used to measure the RF input level via
the test point on the front panel. The RF input level can be adjusted if necessary.
When it is set to broadcast RF input, the actual value of the input level (dB) is
equal to the measurement value +20.0 + 1.0. When it is set to narrowcast RF
input, the actual value of the input level (dB) is equal to the measurement +32.0
+ 1.0.
the test point on the front panel. The RF input level can be adjusted if necessary.
When it is set to broadcast RF input, the actual value of the input level (dB) is
equal to the measurement value +20.0 + 1.0. When it is set to narrowcast RF
input, the actual value of the input level (dB) is equal to the measurement +32.0
+ 1.0.
•
Check whether the optical output power is within the specifications with an
optical power meter. The optical output power lower limit (dB) equals to the
standard value - 0.2; and the optical output power upper limit (dB) equals to
the standard value + 0.5. Make sure the mating surface is clean when testing.
optical power meter. The optical output power lower limit (dB) equals to the
standard value - 0.2; and the optical output power upper limit (dB) equals to
the standard value + 0.5. Make sure the mating surface is clean when testing.
3-4 Operation
OL-29668-02