Cisco Cisco OptoStar II Driver Amplifier Installation Guide

Page of 77
Starting up the Module, Continued 
• 
A DB meter or spectrum analyzer can be used to measure the RF input level via 
the test point on the front panel. The RF input level can be adjusted if necessary. 
When it is set to broadcast RF input, the actual value of the input level (dB) is 
equal to the measurement value +20.0 + 1.0. When it is set to narrowcast RF 
input, the actual value of the input level (dB) is equal to the measurement +32.0 
+ 1.0. 
• 
Check whether the optical output power is within the specifications with an 
optical power meter. The optical output power lower limit (dB) equals to the 
standard value - 0.2; and the optical output power upper limit (dB) equals to 
the standard value + 0.5. Make sure the mating surface is clean when testing. 
 
 
 
 
 
3-4                                            Operation 
  OL-29668-02