Cisco Cisco OptoStar II Driver Amplifier Installation Guide

Page of 77
Operating using ICIM LCD, Continued
 
2.  The RF input signal contains only digital signal. When the RF signal is input 
from the broadcast RF input port, the RF input level equals to the average 
level of the single channel digital signal at the broadcast RF input port. When 
the RF signal is input from the narrowcast RF input port, the RF input level 
plus 12dB equals to the average level of the single channel digital signal at the 
narrowcast RF input port. The forward transmitter detects the total power of 
the RF signal. The average level of single channel digital signal is calculated 
according to the actual channel number and the D-value of analog and digital 
channels as set by the customer. 
For example: Input 0 channel in the analog signal, 114 channels in the digital 
signal, 13 dBmV/channel at the broadcast RF input port, the D-value 
between digital signal and analog signal is set to 0 dB, RF input level displays 
13 dBmV. 
The fiber length is 20km by default (with a selection range of 0 to 20km).  The 
cursor stays in the fiber length field by default: 
1.  Press SET button to start the configuration; 
2.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
3.  Press ▼ button to move the cursor to ”Set” ; 
4.  Press SET button to save the configuration. 
Note: For the module with a transmission distance of 10km, the fiber length is 
10km by default (with a selection range of 0 to 10km). See steps 1 to 4 above for 
configuration procedures. 
 
Continued on next page 
 
 
3-10                                            Operation 
  OL-29668-02