Important Safety Instructions, Continued 
Safety Plugs (USA Only) 
This equipment is equipped with either a 3-terminal (grounding-type) safety plug or 
a 2-terminal (polarized) safety plug. The wide blade or the third terminal is provided 
for safety. Do not defeat the safety purpose of the grounding-type or polarized safety 
plug. 
To properly ground this equipment, follow these safety guidelines: 
• 
Grounding-Type Plug - For a 3-terminal plug (one terminal on this plug is a 
protective grounding pin), insert the plug into a grounded mains, 3-terminal 
outlet. 
Note:
 This plug fits only one way. If this plug cannot be fully inserted into the 
outlet, contact an electrician to replace the obsolete 3-terminal outlet. 
• 
Polarized Plug - For a 2-terminal plug (a polarized plug with one wide blade and 
one narrow blade), insert the plug into a polarized mains, 2-terminal outlet in 
which one socket is wider than the other. 
Note: 
If this plug cannot be fully inserted into the outlet, try reversing the plug. If 
the plug still fails to fit, contact an electrician to replace the obsolete 2-terminal 
outlet. 
Grounding Terminal 
If this equipment is equipped with an external grounding terminal, attach one end of 
an 18-gauge wire (or larger) to the grounding terminal; then, attach the other end of 
the wire to a ground, such as a grounded equipment rack. 
Safety Plugs (European Union) 
• 
Class I Mains Powered Equipment - Provided with a 3-terminal AC inlet and 
requires connection to a 3-terminal mains supply outlet via a 3-terminal power 
cord for proper connection to the protective ground. 
Note: 
The equipotential bonding terminal provided on some equipment is not 
designed to function as a protective ground connection. 
• 
Class II Mains Powered Equipment - Provided with a 2-terminal AC inlet that 
may be connected by a 2-terminal power cord to the mains supply outlet. No 
connection to the protective ground is required as this class of equipment is 
provided with double or reinforced and/or supplementary insulation in addition 
to the basic insulation provided in Class I equipment. 
Note: 
Class II equipment, which is subject to EN 50083-1, is provided with a 
chassis mounted equipotential bonding terminal. See the section titled 
Equipotential Bonding for connection instructions. 
Equipotential Bonding 
If this equipment is equipped with an external chassis terminal marked with the IEC 
60417-5020 chassis icon ( ), the installer should refer to CENELEC standard EN 
50083-1 or IEC standard IEC 60728-11 for correct equipotential bonding connection 
instructions. 