Cisco Cisco OptoStar II Driver Amplifier Installation Guide

Page of 71
Connections, Continued 
Use OptoStar II 4 in 1 Combiner Module for RF Connections 
Use the OptoStar II 4 in 1 combiner module to change the 4-way reverse receiver 
to a module with the working mode of four input signals and one output signal. 
                
 
1.  Select the reverse receiver module to install the 4 in 1 combiner module. 
2.  Hold the 4 in 1 combiner module vertically, with its four ports aligned with 
the four ports on the rear panel of the reverse receiver module. 
3.  Slide the 4 in 1 combiner module in smoothly until it seats completely. 
Note: Check alignment if you feel significant resistance; do not press hard, 
otherwise connector may be damaged. 
4.  Tighten the mounting screws of the 4 in 1 combiner module by hand or 
screwdriver, to secure the combiner module on the rear panel of the reverse 
receiver module. 
Note: The torque of mounting screw is 5 - 6 kgf·cm. 
5.  Repeat the steps above if more 4 in 1 combiner modules need to be installed. 
6.  Connect the RF cables. 
See the illustration below for connections. 
 
 
 
 
 
 
 
OL-29663-03 
Installation 
2-7