Cisco Prisma FiberLinX Modules (1310 1550 nm) Data Sheet
1310 / 1550 nm Gigabit FiberLinX Modules
4
Specifications, continued
Electrical
Twisted Pair Data Port
IEEE 802.3 10Base-T/100Base-TX for data; RJ-45 connector; Half/Full-Duplex operation
Fiber Data Port
IEEE 802.3 100Base-FX for data; SC or ST connectors; Half/Full-Duplex operation
Twisted Pair Management Port
IEEE 802.3 10Base-T/100Base-TX for management; RJ-45 connector; Half/Full-Duplex
operation; can also function as serial port
operation; can also function as serial port
Standards Compliance
IEEE 802.1Q VLAN, 802.1p and 802.3x Flow Control
Software Configuration and/or Monitoring Via:
Prisma MIB
Prisma MIB
(see note 1)
•
Link Status of Ports
• Port
Type
• Fiber
Type
•
SNMP Port (Host/Remote)
•
SNMP Agent IP Address (Host/Remote/Single)
• Link
Partner
•
Traps (Cold Start, Warm Start, Link Up, Link Down, Authentication Failure, Remote
Unit Lost, Remote Unit Back Online, Far End TX Link On and Far End TX Link Off)
Unit Lost, Remote Unit Back Online, Far End TX Link On and Far End TX Link Off)
Prisma MIB - continued
(see note 2)
•
User-Definable Name of Product
•
User-Definable ID/Name of Each Port
• Enable/Disable
Ports
• Enable/Disable
FiberAlert*
•
Set Duplex Mode for Fiber Ports
• Set
Auto-Negotiation/Speed for Twisted Pair Ports
•
Specify the management port
•
Dynamic Bandwidth Control (32 Kbps increments)
MIB-II (RFC 1213)
(see note 1)
• Packets
Transmitted
• Packets
Received
•
Octets (bytes) Transmitted
•
Octets (bytes) Received
•
Plus All Standard MIB II Objects
Transmission Dot 3 (RFC1643)
(see note 1)
• Alignment
Errors
•
Single Collision Frames
•
Multiple Collision Frames
• SQE
Test
Errors
• Deferred
Transmissions
• Late
Collisions
• Excessive
Collisions
• Carrier
Sense
Errors
•
Frame Too Long
•
Internal MAC Transmit Errors
•
Internal MAC Receive Errors
Hardware Configuration
(see note 3)
•
Set port for SNMP management traffic
•
Set mode of operation
Notes:
1.
Parameter can be monitored only via software
2.
Parameter can configured and monitored via software
3.
Parameter must be set via hardware dipswitch