Cisco Cisco Intelligent Automation for Cloud 4.1 Release Notes
10
Cisco Intelligent Automation for Cloud Release Notes
OL-29969-03
Known Issues
CPTA and CPBA Users Can Not Access Demand Management
Removed the permission, “Read Portal Page-Billing Rates (Demand Management)” for CPTA and
CPBA users.
CPBA users.
Known Issues
Configuration Wizard
Problem
Depending on the browser or browser version, the task “Start all other agents” (Configuration Wizard,
STEP 2) will not open the agents page.
STEP 2) will not open the agents page.
Recommendation
You may need to refresh the portal page to re-enable the hyperlink to work again properly.
VDC Clusters
Problem
It is not possible to add a Virtual Data Center (VDC) in cases where the data center does not have a
“cluster.” Cisco Intelligent Automation for Cloud 4.1 does not support data centers with one host (no
“cluster”).
“cluster.” Cisco Intelligent Automation for Cloud 4.1 does not support data centers with one host (no
“cluster”).
Note
A VMware “cluster” is required to complete Day “0” configuration.
Recommendation
Ensure that all VDCs contain one cluster.
Networks POD With More Than 2,000 vLANS
Problem
The following error message occurs when creating a network POD with 2,000 vLANs or more:
“A violation of the maximum number of activity instances within process ‘Create Network POD
Device Mapping Handler.’ The maximum number of activity instances allowed in a single process
instance is 10000.”
Device Mapping Handler.’ The maximum number of activity instances allowed in a single process
instance is 10000.”
Recommendation
The Cisco Process Orchestrator configuration should be modified as follows:
Step 1
In the Process Orchestrator client, choose File > Environment Properties.