Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 126
 
Chapter 5    Maintenance and Troubleshooting 
 
 
 
86 
78-4023013-01 Rev C 
Troubleshooting Alarm Conditions 
Module Alarm Conditions 
If the red ALARM indicator is illuminated or is blinking, check the display on the 
front panel to determine the cause of the alarm. 
Alarm 
Function 
Possible Causes 
Possible Solutions 
LasBias 
Laser Bias Current  
Failed 
Automatic power control 
circuit failure. 
Call Cisco Services for 
assistance. 
LasTemp 
Laser Temperature  
High or Low 
 
Laser temperature out of 
specification. Laser could 
be faulty. 
 
Chassis air filter requires 
changing. 
Call Cisco Services for 
assistance. 
ModTemp  Module Temperature 
High or Low 
Ambient temperature is too 
high due to: 
 
A failure in the building 
air conditioning system. 
 
Airflow through the rack 
has been restricted or cut 
off. 
 
Prisma chassis cooling 
fans are not operating 
properly. 
Ensure the airflow 
system has not been 
damaged or removed. 
Repair or replace fan 
tray as needed. 
To troubleshoot the 
chassis cooling fans, 
refer to Prisma II Chassis 
Installation and 
Operation Guide, part 
number 713375. 
InRF 
RF Input Power 
High or Low 
 
RF source not 
transmitting.  
 
Faulty RF cables or 
connections. 
Check RF source and 
cables and call 
connections. 
OutPwr 
Optical Output Power 
High or Low 
Laser could be faulty. 
Call Cisco Services for 
assistance.