Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 126
 
Chapter 2    Module Installation 
 
 
 
14 
78-4023013-01 Rev C 
Space Requirements 
This is a single-width, half-height module. 
Prisma II Chassis Installation 
When installed in a standard Prisma II Chassis, the module is placed in a host 
module and then inserted into the chassis in slots 5 through 16. 
 
If the module occupies the upper host module position, its slot number is the 
same (5 through 16) as that of the host module. 
 
If the module occupies the lower host module position, its slot number is 16 plus 
the host module slot number, or 21 through 32. 
Slots 1 through 4 are usually reserved for the power supplies. If an ICIM is installed, 
it occupies slots 15 and 16. If an ICIM is not installed, any other module (or host 
module) can occupy these slots. Slots 2 and 4 are reserved for an internal power 
supply, if installed. If an internal power supply is not installed here, any other 
module (or host module) can occupy these slots. 
Prisma II XD Chassis Installation 
When installed in a Prisma II XD Chassis, the module is inserted directly into an 
available application module slot on the chassis front panel. The application module 
slots are numbered 1 through 16. The chassis power supplies and ICIM are installed 
in dedicated slots on the chassis back panel, so slots 1 through 16 are available for 
application modules no matter how the chassis is configured. 
 
Prisma II Chassis Style 
The standard Prisma II chassis may be configured as front-access or rear-access 
depending on the system you have purchased. Power, RF input or output, and other 
connectors may be located on either the front or rear of the chassis. Connections to 
the chassis serve the same function and are made in the same manner regardless of 
the location of the connectors or chassis configuration.