Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 126
 
 
Connecting a Chassis to the TNCS Server 
78-4023013-01 Rev C 
29 
 
Connecting a Chassis to the TNCS Server 
Cable Kits for Connecting a Chassis to the TNCS Server 
Connecting the chassis to the TNCS server requires two special cable kits that are 
available from the factory. 
 
The RS-485 cable kit, part number 735748, includes the following: 
-
 
Breakout boxes, 4 each 
-
 
RS-485 cable assemblies (50 feet), 4 each 
-
 
Breakout box mounting brackets, 4 each 
-
 
6-32 screws (1.25 inches), 100 each 
 
The Prisma II cable kit, part number 738686, includes the following: 
-
 
Prisma II cable assemblies, 4 each 
The RS-485 cable kit is used to communicate with the RS-485/422/TTL devices. 
 
To Connect TNCS to the Chassis EM IN Port 
1  Mount one of the breakout boxes (included in the RS-485 cable kit) in a rack 
location central to the appropriate Prisma II Chassis. 
 
2  Connect a RS-485 cable assembly (included in the RS-485 cable kit) from the 
breakout box to the RS-485 COM port on the TNCS server. 
3  Connect one Prisma II cable assembly (included in the Prisma II cable kit) from 
the breakout box to the EM IN port of each Prisma II Chassis containing an 
ICIM. 
 
Note: As a general rule, it is recommended that the total number of ICIMs connected 
to any single COM port on the TNCS server be limited to four (4). However, you 
may connect more than four ICIMs per TNCS COM port as long as the total number 
of devices (modules) monitored by a single COM port does not exceed four-hundred 
(400) and the total number of devices monitored by any single ICIM does not exceed 
140.