Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 126
 
 
Checking Module Alarms using the ICIM 
78-4023013-01 Rev C 
55 
 
ALARMS Menus 
When a module ALARMS menu is selected, press the 
 
 key or the 
 
 key to 
scroll through alarms. Some typical ALARMS menus are shown below. 
A L A R M S
A L A R M S
S h e l f
5
S l o t
          1 2
S h e l f
5
S l o t
          1 2
H D T x
I n R F
M i n L
H D T x
O u t P w r
M i n H
A L A R M S
A L A R M S
S h e l f
5
S l o t
          1 2
TP559
S h e l f
5
S l o t
          1 2
H D T x
C w M o d e
A l a r m
H D T x
L a s B i a s
M i n H
 
Note: For details on all alarm parameters, see 
Module Parameter Descriptions (on 
page 89). 
 
To Set Adjustable Alarm Thresholds using the ICIM 
You can use the ICIM to change the adjustable alarm thresholds of this module from 
their factory default values. 
1  At the MODULE menu, press the 
STAT
 key. 
Result: The STATUS menu appears on the ICIM LCD. 
2  Press the 
SEL
 key. The alarm thresholds previously set are displayed. If the 
label n/a is displayed, you cannot configure that alarm threshold. Press the 
 
 
key to highlight the alarm threshold for the next parameter. 
3  When the threshold that you wish to set is highlighted, press the 
ENTER
 key. 
4  Press the 
 
 key or the
 
 key to change the increment size. 
5  Press the 
 
 key or the 
 
 key to adjust the alarm threshold. 
Note: Press the Cancel ( 
ALRM
 ) key to return to the previous menu. 
6  Press the 
ENTER
 key to save the changes. 
Result: Data Saved displays. 
7  When finished, press the 
MAIN
 key to return to the MAIN menu.