Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide

Page of 126
 
Chapter 3    Operation using ICIM 
 
 
 
54 
78-4023013-01 Rev C 
Checking Module Alarms using the ICIM 
To Check Alarms using ICIM 
If the red ALARM LED on the front panel is blinking, a minor alarm condition is 
indicated. If the ALARM LED on the front panel is illuminated, a critical alarm 
conditions is indicated. 
Alarms fall into one of the following categories. 
 
Major low 
 
Minor low 
 
Minor high 
 
Major high 
1  From the MAIN menu, press the 
 
 key to highlight the Shelf and Slot fields 
2  Press the 
SEL
 key to address the Shelf number. Then press the 
 
 key or the 
 
 keys to scroll to the number of the desired shelf.     
3  Press the 
ENTER
 key. 
Result:  The Slot field is highlighted. 
4  Press the 
 
 key or the 
 
 key to Scroll to the number of the desired slot.  
5  Press the 
ENTER
 key. 
Result:  The MODULE menu displays on the ICIM. 
6  Press the 
ALRM
 key. 
Result:  Module alarm conditions display. 
7  Use the 
 
 key or the 
 
 key to scroll through alarm conditions until the 
desired alarm is displayed. 
8  Monitor the alarm condition(s).  Take appropriate action. Verify that all settings 
and thresholds relating to the alarm indication are set correctly to rule out an 
unintended alarm.  
9  When finished, press the 
MAIN
 key to return to the MAIN menu.