Cisco GainMaker Optoelectronic Node 1GHz with 42 54 MHz Split Data Sheet
GainMaker High Output Node – 5-40/52-1002 MHz
6
Specifications, continued
Electrical
Units
Notes
Max. AC Through Current (continuous)
Amps
15
Max. AC Through Current (surge)
Amps
25
Component DC Power Consumption (typical)
@ +24 VDC
@ +15 VDC
@ -6 VDC
1
Launch Amplifier High Gain Dual (thermal)
Amps 1.7
-
-
Status Monitoring Transponder
Amps
0.15
-
-
Standard Optical Receiver Amps
0.25
0.01
0.035
Reverse Transmitter – Standard FP
Amps
0.14
-
0.07
Reverse Transmitter – Standard DFB
Amps
0.08
-
0.09
Power Supply DC Current Rating
Amps
3.4
0.05
0.3
1
Station Powering Data
AC Voltage
GainMaker High
Output Node
I
DC
(Amps at
24 V DC)
90
85
80
75
70
65
60
55
50
45
40
AC
Current
(A) 0.91 0.93 0.93 0.95 0.99 1.06 1.24 1.30 1.44 1.60 1.84
1 or 2 RX, 1 TX,
& Stat Mon
2.3
Power
(W)
64.9 64.9 64.7 64.2 64.3 64.6 64.4 64.5 64.4 64.3 65.8
Data is based on stations configured for 2-way operation with status monitoring transponder. AC currents specified are based on
measurements made with typical CATV type ferro-resonant AC power supply (quasi-square wave), and GainMaker High Output Node DC
power supply (3.4 amp, 24 V DC, pn 4022705).
DC supply has a user configurable 40 V or 50 V AC under-voltage lockout circuit.
Note:
1.
The total DC Power consumption of installed components should not exceed the power supply DC current rating.
Environmental
Units
Operating Temperature Range
degrees
-40
°F to 140°F (-40°C to 60°C)
Relative Humidity Range
percent
5% to 95%
Mechanical
Housing Dimensions
Weight
Station with 1 RX, 1 TX, & power supply: 22 lbs (9.9 kg)
Station with 1 RX, 1 TX, & power supply: 22 lbs (9.9 kg)
17.5 in. L x 7.3 in. H x 7.5 in. D
(445 mm L x 185 mm H x 191 mm D)
(445 mm L x 185 mm H x 191 mm D)
Unless otherwise noted, specifications reflect typical performance and are referenced to 68
°F (20°C). Specifications are based
upon measurements made in accordance with SCTE/ANSI standards (where applicable), using standard frequency assignments.