Cisco Cisco TNCS Element Management System Data Sheet

Page of 3
Transponder for Prisma Model 6940/6942/6944 Optical Nodes
 
 
2
 
 
Specifications  
 
Agile Transmitter 
Parameter 
Specification 
Units 
Notes 
Carrier frequency  
5 - 65 
MHz 
Remotely adjustable 
Frequency step size 
200 
kHz 
 
Modulation type 
FSK 
 
Deviation  
± 67 
kHz 
 
Occupied bandwidth  
400 
kHz 
 
RF output level 
24 to 50 
dBmV 
Remotely adjustable 
Output level step size 
2.0 
dB 
 
Level stability 
< ±2.0 
dB 
Over full temperature and frequency range 
Frequency stability 
± 7.5 
kHz 
Over full temperature and frequency range  
Spurious and harmonics (5-2000 MHz) 
> 55 
dBc 
 
Extinction ratio 
> 60  
dBc 
From operational output level   
 
Agile Receiver 
Parameter 
Specification 
Units 
Notes 
Receive carrier frequency 
45-174 
MHz 
Remotely adjustable 
Frequency step size 
200  
kHz 
 
RF input level range 
 –25 to 20 
dBmV 
 
Selectivity at frequency offset of:       
                                                          200 kHz 
                                                         400 kHz 
                                                         800 kHz 
 
+30 
+40 
+50 
 
dBc 
dBc 
dBc 
Specifies the amount an adjacent carrier’s 
level can exceed the transponder receive 
carrier’s level at the transponder input, 
without causing interference 
 
 
Monitored Parameters 
Device 
Parameter 
Units 
Optical Receivers  (RX ‘s 1- 4) 
Optical Receive Power 
mW / dBm 
Optical Transmitters  (TX’s 1-4) 
Optical Transmit Power 
mW / dBm 
Transponder 
RF Input Level 
dBmV 
Node 
Internal Temperature 
deg C / deg F 
Power Supply 
+ 24 V DC Output Voltage 
V DC 
Power Supply 
+ 15 V DC Output Voltage 
V DC 
Power Supply 
  - 6 V DC  Output Voltage 
V DC 
 
 
Controllable Parameters 
Device 
Control Variables 
 
Device 
Control Variables 
Optical RX 1 & 2 Select Switch 
Primary / Secondary 
 
Port 3 Reverse Switch 
Normal / -6 dB / Off 
Optical RX 3 & 4 Select Switch 
Primary / Secondary 
 
Port 4 Reverse Switch 
Normal / -6 dB / Off 
Optical RX 1 & 2 Switch Level 
0-2mW Optical Receive Power  
 
Port 5 Reverse Switch 
Normal / -6 dB / Off 
Optical RX 3 & 4 Switch Level 
0-2mW Optical Receive Power  
 
Port 6 Reverse Switch 
Normal / -6 dB / Off 
Power Supply Monitor 
Monitor 1 / Monitor 2 
 
Common Reverse Switch 
Normal / -6 dB / Off 
Primary Optic Restore Time  
Time primary Optical level must be 
present before returning to primary 
0-255 Seconds 
 
 
 
 
Environmental Specifications 
Parameter 
Specification 
Units 
Notes 
Operating Temperature 
-40
  
to +85 
C  
Humidity 
0 to 90 
Non Condensing