Moxa CP-114UL-I-DB9M Leaflet

Page of 2
1
w w w. m o x a . c o m
i n f o @ m o x a . c o m
Serial Expansion and Extension Solutions
CP-114UL
CP-114UL-I
CP-114UL/UL-I
Over 700 Kbps data throughput for top performance
 
128-byte FIFO and on-chip H/W, S/W flow control
 
Universal PCI compatible with 3.3/5 V PCI and PCI-X
 
Serial communication speed up to 921.6 Kbps
 
Drivers provided for Windows (2000, XP/2003/Vista/2008 x86/
 
x64, 9X/ME/NT), Linux 2.4, Linux 2.6 (x86/x64)
Easy maintenance with on-board LED display
 
On-board 15 KV ESD and 2 KV optical isolation protection
 
 Wide temperature model available for -40 to 85°C  environment
 
4-port RS-232/422/485 Universal PCI serial board with optional 2 KV  
isolation
Overview
Support for Major Windows and Linux/Unix OS drivers
Moxa’s CP-114UL/UL-I series of multiport serial boards are designed 
to be used by industrial automation system integrators for long 
distance, multi-point, PC-based data acquisition applications. On-chip 
Automatic Data Direction Control for precision RS-485 communication 
requires precise timing control to enable and disable the line driver. 
The Moxa Turbo Serial Engine
TM
 chip that powers the CP-114UL/UL-I 
Moxa continues to support a wide variety of operating systems, and 
the CP-114UL/UL-I boards are no exception. Reliable Windows COM 
and Linux/Unix TTY drivers are provided for all Moxa boards, and other 
operating systems, such as WEPOS, are also supported for embedded 
integration.
boards come with on-chip ADDC®, which makes RS-485 as easy to 
use as RS-232. In RS-485 mode, the serial port can connect up to 
31 daisy-chained RS-485 devices within a range of 1.2 km. For long 
distance RS-485 communication, 2 KV optical isolation protections are 
available to prevent equipment damage.
Specifications
Hardware
Comm. Controller: MU860 (16C550C compatible)
Bus: 32-bit Universal PCI
Connector: DB44 female
Serial Interface
Number of Ports: 4
Serial Standards: RS-232/422/485
Max. Number of Boards per PC: 4
ESD Protection: 15 KV on the board
Optical Isolation: 2 KV (CP-114UL-I only)
Performance
Baudrate: 50 bps to 921.6 Kbps
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS, XON/XOFF
I/O Address: Assigned by BIOS
IRQ: Assigned by BIOS
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND
RS-485-4w: TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND
RS-485-2w: Data+(B), Data-(A), GND
Driver Support
Operating Systems: Windows (2000, XP/2003/Vista/2008 x86/x64, 9X/
ME/NT), Linux 2.4, Linux 2.6 (x86/x64)
Physical Characteristics
Dimensions: 
CP-114UL: 64.4 x 120 mm (2.53 x 4.72 in) 
CP-114UL-I: 64.4 x 130 mm (2.53 x 5.12 in)
Environmental Limits
Operating Temperature: 
Standard Models: 0 to 55°C (32 to 131°F) 
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)