Step 2
Select 
Overview > Reporting
.
Step 3
Click the 
Report Templates 
tab.
The Report Templates page appears.
Step 4
Click 
Create Report Template
.
The Report Sections page appears.
Step 5
Type a name for your new report template in the 
Report Title
 field.
Step 6
Click 
Save
 to save the report template under the new name.
The report template is saved and an entry for the report template appears on the Report Templates page.
Step 7
Click the import sections from dashboard, summaries and workflows icon (
).
The Import Report Sections pop-up window appears. You can choose any of the data sources described 
in the 
 table.
Step 8
Select a dashboard, workflow or summary from the drop-down menus.
Step 9
For the data sources you want to add, click 
Import
.
The Report Sections page for your template reappears with a section for each element of the selected 
data source. For dashboards, each widget graphic will have its own section; for workflows, each event 
view will have its own section.
Step 10
Make changes to the content of your sections as needed. 
For information on editing a report template, see 
.
Note
The last report section in some workflows contains detail views that show packets, host profiles, 
or vulnerabilities, depending on the workflow. Retrieving large numbers of events with these 
detail views when generating your report may affect performance of the Defense Center.
Step 11
When the report template is correct, click 
Save
.
The report template is saved and an entry for the report template appears on the Report Templates page.
Generating Reports from a Report Template
License: 
Any
After you define your report template, you are ready to generate the report itself. The generation process 
lets you select the report’s format (HTML, PDF, or CSV). You can also adjust the report’s global time 
window, which applies a consistent time frame to all sections except those you exempt. For information 
on setting the report time window, see 
If the report template includes user input parameters in its search specification, the generation process 
prompts you to enter values, which tailor this run of the report to a subset of the data. For information 
on input parameters, see 
The Reports tab lists all previously generated reports, with report name, date and time of generation, 
generating user, and whether the report is stored locally or remotely. A status column indicates whether 
the report is already generated, is in the generation queue (for example, for scheduled tasks), or failed 