Chapter 55      Using Health Monitoring 
  Configuring Health Policies
You must apply the health policy to the appropriate devices if you want your settings to take effect. See 
 for more information.
Configuring Health Status Monitoring
License: 
Any
Use the Health Monitor Process module to monitor the health of the health monitor on a Defense Center 
by generating alerts when too many minutes elapse between health events received from monitored 
appliances. 
For example, if a Defense Center (
myrtle.example.com
) monitors a device (
dogwood.example.com
), 
you apply a health policy with the Health Monitor Process module enabled to 
myrtle.example.com
. The 
Health Monitor Process module then reports events that indicate how many minutes have elapsed since 
the last event was received from 
dogwood.example.com
.
You can configure the elapsed duration between events, in minutes, that causes an alert to be generated. 
If the wait exceeds the number of minutes configured in the Warning Minutes since last event limit, the 
status classification for that module changes to Warning. If the wait exceeds the Critical Minutes since 
last event limit, the status classification for that module changes to Critical. That status data feeds into 
the health monitor.
The maximum number of minutes you can set for either limit is 144, and the Critical limit must be higher 
than the Warning limit. The minimum number of minutes is 5.
To configure Health Monitor Process module settings:
Access: 
Admin/Maint
Step 1
In the Health Policy Configuration page, select 
Health Monitor Process
.
The Health Policy Configuration — Health Monitor Process page appears.
Step 2
Select 
On
 for the 
Enabled
 option to enable use of the module for health status testing.
Step 3
In the 
Critical Minutes since last event
 field, enter the maximum number of minutes to wait between events, 
before triggering a critical health status.
Step 4
In the 
Warning Minutes since last event
 field, enter the maximum number of minutes to wait between 
events, before triggering a warning health status.
Step 5
You have three options:
  •
To save your changes to this module and return to the Health Policy page, click 
Save Policy and Exit
.
  •
To return to the Health Policy page without saving any of your settings for this module, click 
Cancel
.
  •
To temporarily save your changes to this module and switch to another module’s settings to modify, 
select the other module from the list at the left of the page. If you click 
Save Policy and Exit
 when you 
are done, all changes you made will be saved; if you click 
Cancel
, you discard all changes.
You must apply the health policy to the Defense Center for your settings to take effect. See 