If there is a misconfiguration in switch IDs (when both switches have the same switch ID), the formation of the VSL 
will fail on initialization. When the two chassis are being brought up as a single Cisco Virtual Switching System, the 
VSL initialization handshake verifies that the switch IDs of the two chassis do not match. If the switch ID is found to 
be in conflict, the VSL will not become active. If this situation occurs, both chassis assume the role of active virtual 
switch and you are informed of this conflict. 
Conversion to Virtual Switch Mode 
This section details the steps required to convert a standalone system into virtual switch mode. The interfaces 
forming the VSL should be connected prior to the conversion process, to minimize the number of times the chassis 
is reloaded. Additionally, you should begin the conversion process using a default configuration, as the conversion 
process removes any previous configuration that exists on the standalone chassis. Refer to Figure 11 to reference 
the conversion process. 
Figure 11.    Cisco Virtual Switching System Conversion 
 
Step 1.   Configure virtual switch ID and domain.  
On the two switches, configure the same virtual 
switch domain number (in this case it is 100), but 
unique switch IDs using the following configuration 
mode commands:
 VSS-sw1#conf t 
Enter configuration commands, one per 
line. End with CNTL/Z.  
VSS-sw1(config)#switch virtual domain 
100 
Domain ID 100 config will take effect 
only  
after the exec command ‘switch convert 
mode virtual’ is issued  
VSS-sw1(config-vs-domain)#switch 1  
VSS-sw1(config-vs-domain)#  
VSS-sw2#conf t  
Enter configuration commands, one per 
line. End with CNTL/Z.  
VSS-sw2(config)#switch virtual domain 
100 
Domain ID 100 config will take effect 
only  
after the exec command ‘switch convert 
mode virtual’ is issued  
VSS-sw2(config-vs-domain)#switch 2  
VSS-sw2(config-vs-domain)#  
Note that as a result of this command, the domain ID is retained in the configuration, but the switch ID is not; this 
value is stored as a variable in ROMmon. It can be confirmed by issuing the following command on each switch: 
VSS-sw1#switch read switch_num  
Read switch_num 
 from rommon is 1  
VSS-sw2#switch read switch_num  
Read switch_num from rommon is 2