Cisco Cisco SG300-28 28-Port Gigabit Managed Switch Technical References

Page of 1117
Network Management Protocol (SNMP) Commands
865
OL-32830-01 Command Line Interface Reference Guide
45
excluded—Specifies that the view type is excluded.
oid-tree—(Optional) Specifies the ASN.1 subtree object identifier to be 
included or excluded from the view. To identify the subtree, specify a text 
string consisting of numbers, such as 1.3.6.2.4, or a word, such as System 
and, optionally, a sequence of numbers. Replace a single sub-identifier with 
the asterisk (*) wildcard to specify a subtree family; for example 1.3.*.4. This 
parameter depends on the MIB being specified.
Default Configuration
The following views are created by default:
Default—Contains all MIBs except for those that configure the SNMP 
parameters themselves. 
DefaultSuper—Contains all MIBs.
Command Mode
Global Configuration mode
User Guidelines
This command can be entered multiple times for the same view.
The command’s logical key is the pair (view-name, oid-tree). Therefore there 
cannot be two commands with the same view-name and oid-tree.
The number of views is limited to 64.
Default and DefaultSuper views are reserved for internal software use and cannot 
be deleted or modified.
Example
The following example creates a view that includes all objects in the MIB-II system 
group except for sysServices (System 7) and all objects for interface 1 in the 
MIB-II interface group (this format is specified on the parameters specified in 
ifEntry). 
switchxxxxxx(config)# 
snmp-server view
 
user-view system included
switchxxxxxx(config)# 
snmp-server view
 
user-view system.7 excluded
switchxxxxxx(config)# 
snmp-server view
 
user-view ifEntry.*.1 included