Updating Your Appliances
When to Perform the Update
Because the update process may affect traffic inspection, traffic flow, and link 
state, Sourcefire strongly recommends you perform the update in a 
maintenance window or at a time when the interruption will have the least impact 
on your deployment.
Installation Method
Use the Defense Center’s web interface to perform the update. Update the 
Defense Center first, then use it to update the devices it manages.
Order of Installation
Update your Defense Centers before updating the devices they manage.
Installing the Update on Clustered Devices
When you install an update on clustered devices, the system performs the 
update on the devices one at a time. When the update starts, the system first 
applies it to the secondary device, which goes into maintenance mode until any 
necessary processes restart and the device is processing traffic again. The 
system then applies the update to the primary device, which follows the same 
process.
Installing the Update on Stacked Devices
When you install an update on stacked devices, the system performs the updates 
simultaneously. Each device resumes normal operation when the update 
completes. Note that:
If the primary device completes the update before all of the secondary 
devices, the stack operates in a limited, mixed-version state until all devices 
have completed the update. 
If the primary device completes the update after all of the secondary 
devices, the stack resumes normal operation when the update completes 
on the primary device.
Installing the Update on X-Series Devices
Note that if you uninstall a version of Cisco NGIPS for Blue Coat X-Series, you 
must restart the VAP before a new installation. This process can take several 
minutes.
To update to Version 5.3.0.6, Sourcefire Software for X-Series must be running at 
least Version 5.3.
You cannot update Sourcefire Software for X-Series running Version 4.10.x to 
Version 5.3.0.6. Instead, you must uninstall the previous version and then install 
Version 5.3 before updating to Version 5.3.0.6. For detailed instructions, see the 
Sourcefire Software for X-Series Installation and Configuration Guide.